  Aluminum Wiring
Aluminum Wiring

Aluminum wiring was used in the 1970's for the wiring of receptacles and switches. Single stranded branch aluminum wiring, has been implicated with fires in houses. Aluminum does not conduct electricity as efficiently as copper and creates more resistance and heat. The wire expands and contracts more than copper. The problem was compounded by screw heads which were too small at the devices. This expanding and contracting are susceptible to working the connections loose at the receptacles and switches. This is where a short can occur as oxidation builds up between the aluminum wires, and pose a potential fire hazard. Updated devices with larger screws were created however, these are not considered the best or only solution. Some people feel the aluminum should be removed and copper replaced. There are some approved and accepted methods. Standard wire nuts are not approved for pig tailing and according to the Consumer Product Safety Commission may be a greater fire hazard and should be repaired.

Approved Methods According to the Consumer Product Safety Commission include:

  • Copper pig-tails crimped onto the aluminum at all receptacles and switches. A special tool is used for this application.
  • UL. approved wire nut connectors, filled with anti-oxidant cream, designed specifically for aluminum to copper connections.
  • Secure connections as is on approved Al/Cu devices.
  • Use antioxidant on all aluminum wiring connections

Monitor conditions such as flickering lights, voltage drop, or warm receptacles. In any case, an electrician familiar with aluminum wiring should be consulted to verify proper connections. Multi stranded aluminum wiring is not part of this problem and of no concern. The majority of modern 220 amp rated houses are utilizing multi stranded aluminum wiring.

COPPER CLAD ALUMINUM

Copper Clad Aluminum is easily mistaken for copper. It does not have the same problem with oxidation build up as does aluminum. It is typically a # 12 wire and still needs proper devices with the larger screw heads or approved pig tailing methods. To identify Copper Clad Aluminum look for a silver color at the ends of the wires where they are connected to the grounding bar. Another location to identify Copper Clad Aluminum is in the attic or crawlspace. In these areas look for the identification on the wire sheathing such as CU Clad AL.

S. SHOWALTER, The Home Inspector's Guide to Training he Real Estate Professional, Aluminum (2d ed. 1998).

Need Help?
Enter a search topic below:
Quick Home Search
Looking for a new home! Access the MLS instantly by selecting a county below.
ADCMaps - The Map People
Order You Credit Report Online
About your Agent, Simon Kim
Simon is one of Keller Williams® top producing Realtors®. You can be sure that when you work with Simon, he'll understand your needs. Contact Simon and benefit from the services of an experienced and professional Realtor®.

Simon Kim, Realtor®
Keller Williams Advantage Realty

15400 Cahoun Dr., Suite 180
Rockville, Maryland 20855

Direct: 301-963-7060
Fax: 301-576-8633
Office: 301-251-1221
E-mail:

Learn more About Simon

SimonHomes.com
Control Panel
Equal Housing Opportunity Icon

Home | Buying Real Estate | Selling Real Estate | Relocating | Information | Contact Us | About Us
Terms of Use and Disclaimer | Site Map | All Rights Reserved
Maryland Real Estate | Copyright © 2001 The Rrien Group, Ltd.

"Disclosure: Information about Maryland real estate broker listed homes for sale from the Internet Data Exchange (IDX) contained in this website is provided by the Metropolitan Regional Information System (MRIS) through participating IDX brokers."

Mojo Web Solutions